Truck And Trailer Door Lock Series Trailer Door Lock,Trailer Coupler Lock ,Cargo Trailer Door Locks ,Trailer Door Hinges Truck Trailer Co., Ltd. , http://www.nbrollershutters.com
HPLC, IC, ICP-MS, TOC nanlysis, organic nanlysis, CF-AAS, Toxicology research, capillary electrophoresis,
Environmental protection experimental analysis
2)Flow schematic PF+KDF+AC+RO+UV+AC+DI+TF
LV. 1 5μ M spun fiber filter
LV. 2 Mixed KDF filter
LV. 3 Granular active carbon filter
LV. 4 100GPD RO membrane
LV. 5 Double (254&185nm) wavelength UV lamp
LV. 6 Post active carbon filter
LV. 7 Ultra pure polishing resin cartridge
LV. 8 (0.45+0.1)μ M importing PES terminal filter
3)After-sales
· The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:
(1). Damage caused by maloperation or use in abnormal situations.
(2). Disassembly any part of the machine or human-behavior damage.
(3). Not repaired by our serviceman.
As a rich experience of pure water system manufacturer, Hitech uphold the common development concept with customers, and provide professional pre-sales support and after-sales service. We promise:
12months for maintenance(except consumables).
On site installation supervision.
Free system update service.
Periodically return service.
Service hotline-400.
Model
Standard
Eliminating endotoxin
Low TOC
Comprehensive
Master-S
Master-S UF
Master-S UV
Master-S UVF
Master-S plus
Master-S plus UF
Master-S plus UV
Master-S plus UVF
Flow procedure
PF+KDF+AC+RO+AC+DI+TF
PF+KDF+AC+RO+AC+DI+UF+TF
PF+KDF+AC+RO+UV+AC+DI+TF
PF+KDF+AC+RO+UV+AC+DI+UF+TF
Application
GC,HPLC,IC,ICP
PCR, weather analysis
Amino acid analysis
Reagent preparation
Molecular biology
Cell and tissue cultivation
Life science, IVF
electrophoresis
HPLC,IC,ICP-MS
TOC and organism analysis
CF-AAS, toxicology study
Environmental analysis
HPLC,IC,ICP-MS,CF-AAS, Physics, electrochemistry, Molecular biology, Cell cultivation
Ultrapure water
quality
Resistivity
18.2MΩ.cm@25ºC
Heavy metal ions
< 0.1ppb
TOC
<10 ppb
<3 ppb
Bacteria
<1CFU/ml
Endotoxin
-
<0.001EU/ml
-
<0.001EU/ml
Particle(>0.22μm)
<1/ml
RO water quality
< TDS(ppm, mg/l) of tap water×5%
Technical
specification
Output(25 ºC )
15 Liters/hour* (plus model:30 Liters/hour*)
Flow rate
2 liters/min(with pressure tank)
Pure water outlet
RO water, ultrapure water
Dimension/Weight
Length×Width×Height:50×36×54cm / 20-30Kg
Electric requirements
AC110-220V,50/60Hz,120W
Control
system
Mode display
Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing remind
Safety
low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection
System monitor
Monitoring quality of feed water, RO water and ultrapure water, temperature, used and left time of consumables
Feed water requirement
Tap water, inlet TDS<200 ppm,5-45ºC, 1.0-4.0 kgf/cm 2
 (if inlet TDS>200ppm, extra pretreatment is recommended)
Purification
system
Pretreatment unit
5μm spun fiber filter×1+Kinetic degradation fluxion filter×1+Granular active carbon filter×1
RO unit
100 GPD RO membrane×1 ( Plus model:100 GPD RO membrane×2)
Subsequent unit
Post active carbon filter×1+Ultrapure polishing resin cartridge× 4+(0.45+0.1) μm terminal filter×1
UV model:+Double wavelength(185&254)nm UV lamp cartridge×1
UF model:+5000 Doulton UF cartridge×1
UVFmodel:+Double wavelength(185&254)nm UV lamp cartridge×1+5000 Doulton UF cartridge×1
Standard configuration
Main body(including:1 set cartridge)+4 gallon tank + accessory box
China-Water-Purification-System-Used-for-Buffer-and-Reagent-Preparation-Microbiology-Media-Preparation
1)Application